{"product_id":"aerotest-simultan","title":"Aerotest Simultan","description":"\u003cdiv class=\"container flex flex-col md:flex-row flex-wrap my-6 lg:mt-8 product-title text-h1 xl:text-h1xl font-titles px-0 mt-0 md:mt-10 mb-5 md:mb-10\"\u003e\n\u003ch1 class=\"page-title\"\u003e\u003cspan class=\"base\"\u003eAEROTEST SIMULTAN\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"w-full mb-6\"\u003e\n\u003cdiv class=\"product-subtitle\"\u003e\n\u003ch3 class=\"font-titlesbold text-h3 xl:text-h4 mb-6\"\u003eMobile test system for breathing air and Nitrox applications up to 300 bar\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mb-6 product-description prose text-lg\"\u003eThe portable AEROTEST SIMULTAN test system enables reliable analysis of breathing air and Nitrox in accordance with DIN EN 12021, using detector tubes and an impactor.\u003c\/div\u003e\n\u003cdiv class=\"product-highlights mb-6\"\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures CO, CO₂, water vapor, and residual oil\u003c\/li\u003e\n\u003cli\u003eCompact design for mobile use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"container px-0 lg:px-5 my-72 xl:my-120\"\u003e\n\u003cdiv class=\"jsonTable aos-pdp-table\"\u003e\n\u003cdiv class=\"ProductDataTableContainer\"\u003e\n\u003ch2 class=\"productDataTable_text\"\u003eTechnical data\u003c\/h2\u003e\n\u003ch3 class=\"productDataTable_text\"\u003eAEROTEST HP\u003c\/h3\u003e\n\u003cdiv class=\"productTableWrapper\"\u003e\n\u003ctable class=\"productDataTable_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cspan class=\"bold\"\u003eCarrying case\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eLength × Width × Height (mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e350 × 300 × 85\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eColor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBlack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eWeight with contents\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCa. 3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003e\u003cspan class=\"bold\"\u003ePressure reducer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eInlet\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExternal thread G5\/8–300 bar (hand connection)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eMax. inlet pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003ePressure gauge\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 - 400 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eOutlet\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 mm quick connector for measuring device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eOverpressure valve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSet to 10⁺² bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan class=\"bold\"\u003eAdapter 1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eInlet\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal thread G5\/8–200 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eOutlet\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal thread G5\/8–300 bar for pressure reducer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan class=\"bold\"\u003eAdapter 2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eInlet\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal thread G5\/8-200 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eOutlet\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal thread G5\/8-300 bar for pressure reducer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan class=\"bold\"\u003eMeasuring device\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eLength × Width (mm):\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 × 38\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eHeight including Dräger tube holder (mm):\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eConnection for compressed air supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 mm plug-in nipple\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eInlet pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eFactory-set on delivery:\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8,5 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan class=\"bold\"\u003eVolume flow\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eCO and CO₂ tubes:\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,2 l\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eImpactor and H₂O tubes:\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 l\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"productDataTable_text\"\u003eAEROTEST ALPHA\u003c\/h3\u003e\n\u003cdiv class=\"productTableWrapper\"\u003e\n\u003ctable class=\"productDataTable_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cspan class=\"bold\"\u003eCarrying case\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eLength × Width × Height (mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e350 × 300 × 85\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eColor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBlack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eWeight with contents\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCa. 3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003e\u003cspan class=\"bold\"\u003ePressure reducer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eInlet\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eplug-in nipple\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eMax. inlet pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003ePressure gauge\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,3 - 15 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eOutlet\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 mm quick connector for measuring device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eOverpressure valve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithout\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan class=\"bold\"\u003eAdapter 1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eInlet\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 mm quick connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eOutlet\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExternal thread G 1\/4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan class=\"bold\"\u003eAdapter 2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eInlet\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal thread G 1\/4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eOutlet\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eplug-in nipple 12 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan class=\"bold\"\u003eMeasuring device\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eLength × Width (mm):\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 × 38\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eHeight including Dräger tube holder (mm):\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eConnection for compressed air supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 mm plug-in nipple\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eInlet pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eFactory-set on delivery:\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3,0 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan class=\"bold\"\u003eVolume flow\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eCO and CO₂ tubes:\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,2 l\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bold\"\u003eImpactor and H₂O tubes:\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 l\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"grid aos-description container w-full mx-auto mt-12 lg:mt-20 xl:mt-120 px-0\"\u003e\n\u003cul class=\"aos-product-data accordion\"\u003e\n\u003cli id=\"description\" class=\"relative py-3\"\u003e\n\u003cdiv class=\"accordion-content relative overflow-hidden transition-all duration-700 box-content\"\u003e\n\u003cdiv class=\"prose\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"aos-title-description\"\u003e\n\u003ch2 class=\"aos-heading\"\u003eDetails \u0026amp; Features\u003c\/h2\u003e\n\u003cdiv class=\"aos-text\"\u003e\n\u003cp class=\"ewa-rteLine\"\u003eThe portable breathing air tester AEROTEST SIMULTAN HP enables reliable purity measurement of compressed air. Using detector tubes, CO, CO₂, and water vapor are measured simultaneously; an impactor detects mineral and synthetic oils. Incorrect results due to user error are virtually eliminated, and no calibration is required. A pressure reducer with special nozzles ensures constant flow rate and consistent measurement accuracy.\u003c\/p\u003e\n\u003cp class=\"ewa-rteLine\"\u003eThe AEROTEST SIMULTAN HP checks compliance with DIN EN 12021, offering reliable protection for both health and equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"aos-title-description\"\u003e\n\u003ch2 class=\"aos-heading\"\u003eMeasurement principle\u003c\/h2\u003e\n\u003cdiv class=\"aos-text\"\u003e\n\u003cp class=\"ewa-rteLine\"\u003eTo detect oil content, compressed air flows through 20 nozzles directly onto a glass impaction plate in the impactor. Due to their mass inertia, oil aerosols are deposited, filling the recesses of the glass surface and reducing light scattering – making even minimal oil quantities visible. The specific nozzle arrangement enables quantitative evaluation, regardless of the oil type. Vaporized oils are not detected under typical operating temperatures.\u003c\/p\u003e\n\u003cp class=\"ewa-rteLine\"\u003eTo conduct the measurement, the AEROTEST SIMULTAN HP is connected to a compressor, cylinder, or pipeline. After at least three minutes of flushing (without the impactor), the measurement is performed at 4 l\/min. The impactor is inserted first, followed by the detector tube. The measurement takes five minutes. The protective foil is then removed and the result is read.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"BAUER","offers":[{"title":"Default Title","offer_id":46425264193686,"sku":null,"price":0.0,"currency_code":"MVR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0410\/9038\/4022\/files\/2015-03_aerotest_simultan_hp_rs.jpg?v=1781784449","url":"https:\/\/www.maservices.com.mv\/products\/aerotest-simultan","provider":"Complete Diving Solutions Shop","version":"1.0","type":"link"}